KQ2800KDT超声波清洗器是采用先进、成熟的电路设计制造的;元器件采用优质的器件,并经过严格的质量检验;再经过先进的加工工艺制造而成的新一代功率超声清洗设备,工作可靠,效率高,输出功率稳定。下面是该系列超声波清洗器使用方法和注意事项中英文对照版,KQ2800KDT
超声波清洗器必须严格按以下说明操作:
1、供电电源线应接AC.220V电源,其中红线为火线,绿线为零线,黑线为接地,与地线相连。电源电压应保持在220v±10%的范围内,电压过低将导致继电器不能可靠吸合,电压过高将导致超声波发生器损坏,(注意:供电电源必须有漏电保护开关!)。Voltage for 220V, Power Voltage will be in between 220V+10% and 220V-10%, low voltage will cause relay couldn’t liable connection, high voltage will cause the demage of ultrasonic generator.
2、超声波清洗槽最佳清洗温度在40℃左右,严禁清洗槽内无水开机,否则会因空载而损坏机器,切忌!ultrasonic cleaning tank’s temperature for 40degree, prohibiting no-water operation in cleaning tank, or else it will demage mchine, attention!
3、超声波发生器里面的风机是供整机散热的,应保证其正常运转和散热通道的畅通。the fun of ultrasonic generator is to provide heat elimination , so we should keep nomal operation and good intake of heat elimination
4、超声波清洗机应置于干燥、无腐蚀性的环境中,温度应低于30摄氏度。to put ultrasonic cleaner in dry place, non-corrosion’s environment, the temp is not exceeds 30 degree.
5、本机作用说明:A、超声波功能使用:将超声开关(ULTRASONIC)推至ON位置,稍等片刻,超声波工作,进行工件清洗(超声波工作时间受定时器控制)。B、定时器使用:
定时范围:0S——99.99H拔码开关中间的显示数字为设定的时间。其中,中间的加减调整为:H、M、S H代表小时;M代表分钟; S代表秒;其它拔码调整为0——9 例如:12 S 22 为12.22秒 30M55 为30.55分 99H99 为99.99小时 C、加热及温控使用说明将加热开关(HEATING)推至ON位置,几秒钟后,温控仪将显示测量温度与控制温度。上面显示的是测量温度,下面显示的是控制温度,当测量温度低于控制温度时,温控仪上OUT灯亮,处于加热状态;当测量温度高于控制温度时,温控仪上OUT灯灭,停止加热。控制温度设置方法:按SET键—进入SP菜单---按向上或向下箭头调整温度,调完后按SET键退出即可。
6、严禁带电拆机或检修!to draw out power when we dismantal machine.